2-Position Chilling/Heating Plate with Expanded Chilling
Chill, heat or freeze two separate sets of samples at two separate temperatures with individual control from -20°C to 100°C without a sample block. These completely solid-state 2-Position Chilling/Heating Dry Baths are versatile, reliable, and easy to use. Each heating/chilling station has its own Peltier module, and the entire unit has only two moving parts: the fans. Each plate can be set separately for any temperature within the range of the unit without interaction between the plates. It has simple digital controls and a two-line alphanumeric digital display that is backlit for easy viewing. The display shows the target and actual temperatures of both plates.
The chilling/heating surfaces are each 2.875” (7.3 cm) x 4.375” (11.1 cm) aluminum plates that are very flat for optimal contact with the sample blocks. When unloaded, the plates will reach below 0°C in under two minutes. They will heat to 37°C in under a minute. The chilling and heating rates will change with loads. For instance, temperatures to 4.0°C can be reached on sample blocks as large as 4” (10.2 cm) x 3” (7.6 cm) x 6” (15.2 cm) in about 30 minutes.
Units come complete with a bench-top power supply, instruction manual, and AC line cord. Sample blocks and covers are available as accessories and are shown on the price list.
Features
- Energy-efficient Peltier design
- Digital control to 1°C from -20°C to 100°C without sample block
- 2 separate temperatures on separate plates or both the same if wanted
- Sample blocks for 0.2, 0.5 and 1.5 ml centrifuge tubes, 96-well and 384-well assay plates, 2ml vials, various sizes of test tubes and more.
- Control at room temperature
- 2 countdown timers (up to 30 days each) with alarm
- RS232 I/O port for control or data collection
- 2 data loggers
- Electronic calibration
- Compact size. Small footprint on the bench
- UL, CSA and CE compliant
- 12-month warranty
Applications
- Maintaining 14°C for ligation reactions
- Enzyme reactions and deactivations
- Hybridizations
- Maintaining 17°C for storing oocytes
- Storing samples at ice bucket temperatures
- Incubate samples in 96-well assay plates, or in aluminum blocks holding 0.2 ml, 0.5 ml or 1.5 ml centrifuge tubes and more
- Storing enzymes or DNA libraries at your work station
- Freezing and storing most any small sample at your workstation
- Chilling reagents in insulated blocks of volumes up to 250 ml
- General molecular biology applications
Specifications
Temperature
- Range on each plate: -20°C to 100°C
- Readabilit:y 1°C
- Accuracy: ±1°C
- Stability: ±1°C
- Sensor Platinum: RTD
- Controller Type: PID
- Uniformity: ±0.5°C
Timers
- Range: 00:01 seconds to 30 days
- Readability: 1 second
- Audible Alarm: Yes, alarm sounds for 1 minute. Timer counts up until turned off.
- Auto-Off: Yes, user settable
Data Logger
- Sample times: 1 sec, 1 min or 5 minutes per data point
- Capability: 8110 data points
Electrical
- Heater/Chiller: 50 watts each station. 100 watts total
- Operating Voltages: 90–265 Volts AC input to bench-top power supply, which provides 12 Volts DC to the unit
- Power Consumption: 100 watts
- Power Switch: Yes
Dimensions
- Width: 6.5” (16.5 cm)
- Depth: 14” (35.56 cm)
- Height: 3.5” (8.9 cm)
- Weight: 13 lbs (5.85 kg)
SKU | I174044 |
---|---|
Modelo del fabricante | IC22XT |
Marca | Torrey Pines Scientific |
Ajuste | Digital |
Rango | 20° to 100°C |
Entrada | 90 to 265V |